Nicholson steam trap, 1 fnpt connections, 3516 end to. Thermodynamic steam trap with filter for the extraction of steam condensates. Industrial steam traps, drain traps, orifice unions, uniflex unions, steam trap test valves, pressure powered pumps. Its compact design makes the stainless steel disc the only moving part. Nicholson steam trap, located in walden, new york, has been producing a full line of steam specialties including steam traps, condensate pumps, sanitary steam traps, air traps and drain orifice unions since 1883. This steam trap has all stainless steel internal components. Nicholson steam trappartsnicholson parts nicholson. Nicholson 34 ftn15 steam trap steam depot enterprises, llc.
Steam specialty sales engineering guide contains charts, tables, sizing, design guidelines, and typical piping schematics for steam systems, air systems, and water systems. We are on call 247 and provide personalized customer service, with no minimum orders, accept all major credit cards and open and account while you wait. Control specialties carries top quality equipment from nicholson steam as well as hard to find parts and accessories. Float shall actuate the valve via a hinged lever and linkage. Looking for nicholson steam trap, 1 fnpt connections, 812 end to end length, condensate capacity lbshr 3100 15x144. Nicholson cds series sanitary thermostatic steam trap nicholson s model cds204, installed with the optional b bellows, is the most sensitive trap in the market with a 1c 23f subcool. Nicholson steam trap, 1 fnpt connections, 3516 end. At6screwed type at6fflanged type thermostatic type steam trap. Nicholson steam trap has a policy of continuous product research and improvement and reserves the right to change design and specifications without. Test valves accessories for steam traps steam traps. Spence engineering acquired the nicholson line in 1989 and spence engineering and. The company has just released a new edition of its handbook which includes a newly updated steam trapping primer for sizing steam and condensate lines. On startup, valve is normally open to discharge air, noncondensibles and condensate.
These traps shall have a heavy cast iron body, hardened stainless steel valve. Drain and air can be discharged out smoothly at the startup of steam flow. Steam traps are used for removing the liquid condensate from pipings, heat exchangers, autoclaves, tanks in the chemical industry, for trace heating of dryers, boilers etc. This article reports on laboratory tests proving a modified bellows in a standard steam trap can hold to the 6 in. Most steam traps pass noncondensable gases like air while remaining tight to live steam.
Emerson is where technology and engineering come together to create solutions for the benefit of our customers, driven without compromise for a world in action. Other trap types such as disc, bucket, or balanced pressure thermostatic can be used provided that the collecting leg is adequately sized to prevent backup into the steam main. Thermostatic steam traps operate based on the difference in temperature of the condensate and the steam. Included in the nicholson steam traps we provide is the mechanical steam trap which can be used in a number of applications such as steam lines, process equipment, steam cookers, steam. Nicholson duraflo cast iron inverted bucket steam traps 0043228 nicholson bucket traps provide efficient condensate drainage of virtually all types of steam using equipment. Steam traps, pressure motive condensate pumps, drain traps and uniflex pipe couplings. Air vent shall be of balanced pressure design with stainless steel welded encapsulated bellows capable of discharging air and noncondensable gases continuously. Imagine 15psi steam blowing past a failed trap into the condensate return line. Steam trap function steam traps are automatic valves used in every steam system to remove condensate, air, and other noncondensable gases while preventing or minimizing the passing of steam. The nicholson nova nft 250 series variable orfice steam trap allows pressure up to 250 psig 17. Nova nft650 series variable orifice steam traps ntd 600 series thermoactive steam traps s610 series thermodynamic steam trap s650 series thermoactive steam trap ss600 series noise diffuser steam.
Easy online ordering for the ones who get it done along with 247 customer service, free. In fact, steam trap leaks can account for a 510% loss of steam production energy costs because of the time delay between trap failure and proper diagnosis and maintenance. It can be installed freely in horizontal and vertical pipe. Nicholson fte10 steam trap is designed to be resistant to water hammer and corrosion and pressures up to 464 psig and temperatures up to 850 degrees f. Nicholson steam traps provide longevity and easy maintenance.
Designing a shorter vertical leg for sanitary steam traps. High sensitivity, immediate air venting and exceptional thermal efficiency are the hallmark of nicholson thermostatic steam traps. B3312 straight thru trap b4334 straight thru trap b531 straight thru trap b63114 straight thru trap b73112 straight thru trap b832 straight thru trap add hc to end of model number for high capacity. Nicholson steam traps product information control products. At startup the trap is open and air and condensate enters the trap body.
Steam trap shall be of float and thermostatic design. Download spence brochure nicholson steam traps and condensate pumps are designed for industrial applications such as condensate systems, district heating, main steam systems, process control, and process heating. This pattern allows steam to enter from one side of the trap, and the condensate to discharge from the opposite side of the trap. In inverted bucket steam traps, the bucket within the trap is attached to a lever that opens and closes the trap valve in response to the buckets motion. Looking for nicholson steam trap, 38 fnpt connections, 2 end to end length, condensate capacity lbshr 1250 4dxl7.
This means that sip system temperatures can be set lower and. Included in the nicholson steam traps we provide is the mechanical steam trap which can be used in a number of applications such as steam lines, process equipment, steam cookers, steam heated vats, pressing machinery, unit heaters, oil preheaters, converters, coils, and rotating drums. However, a typical steam system can be a complex network. The nicholson model cds 204 steam trap, with the b bellows is the most sensitive in the market 1. Nicholson steam traps include industrial and process steam traps. For latin america, europe, middle eastafrica and asia, please contact spence engineering. The thermostatic vent will close just prior to saturation temperature. Steam traps nicholson steam trap exporter from coimbatore. When steam or air flows into the underside of the inverted bucket and condensate surrounds it on the outside, the steam causes the bucket to become buoyant and rise. The difference between the manual steam trap and the automated steam trap is that the automated version will emit steam if there is an entity moving in front of it, and can be turned off using a redstone signal, rather. The ntd600 is suitable for pressures through 600 psi and available in 38 inch through 1 inch in size.
A steam trap is a self contained valve which automatically drains the condensate from a steam containing enclosure while remaining tight to live steam, or if necessary, allowing steam to flow at a controlled or adjusted rate. No reason for them to just grow old in our warehouse. Emersons easytoinstall wireless acoustic transmitters can help monitor steam trap. Spence engineered steam specialty and fluid control products meet the changing needs ot todays hvac and industrial marketplaces. Installation tips for steam traps on steam mains tlv a. Looking for nicholson steam trap, 250 psi, 450f, 414 in. Nicholson steam trap repair kit store room 172218 total of 41 units. Applications unit heaters pipe coils blast coils steam. The pressure on the discharge side of any trap draining into the same line as the failed trap. Spence engineering acquired the nicholson line in 1989 and spence engineering and nicholson steam trap received iso9001 certification as manufacturers of fluid control and steam. Most steam traps will also pass noncondensable gases while remaining tight to live steam. Nicholson steam trap is a division of spence engineering company. Steam traps provide the basic function of condensate removal in a steam system.
Matching a trap to a specific drainage application must take into account the various operating principles of steam traps as well as the specific need and conditions. Keystone steam supplies has the steam trap repair index to help you pick. Download nicholsonsteamtrap aseriesdatasheet95731051. When installing a steam trap on a steam main, tlv typically recommends the use of traps that discharge condensate continuously, such as the free float type. Clean steam products spence engineering group, inc. Steam specialty sales carries spence engineering for industrial steam traps, drain traps, orifice unions, uniflex unions, steam trap test valves, pressure powered pumps. This pattern allows steam to enter from one side of the trap, and the condensate to discharge from the same side of the trap. Nova nft650 series variable orifice steam traps ntd 600 series thermoactive steam traps s610 series thermodynamic steam trap s650 series.
The originator of the bellows actuated thermostatic steam trap, nicholson thermostatic product range spans applications from critical tracing to high capacity process. Looking for nicholson steam trap, 1 fnpt connections, 3516 end to end length, condensate capacity lbshr 4700 4dxn1. The nova nft 250 series variable orfice steam trap allows pressure up to 250 psig 17. Nicholson steam steam traps, drainers and steam specialties. The nicholson steam trap product line is designed expressly for the industrial marketplace and features traps ranging from highly polished stainless steel. The pressure on the discharge side of any trap draining into the same line as the failed trap is now much higher than anticipated, so we no longer have a pressure differential across the other traps. The balanced design will allow venting of noncondensibles that collect in the float chamber when operating at design pressure.
Resists water hammer and protects against erosion and corrosion. Looking for armstrong international steam trap, 34 fnpt connections, 278 end to end length, condensate capacity lbshr 1700 36y301. The body of this steam trap is composed of stainless steel. The wsttv steam trap test valve offers simple, immediate, and visible diagnosis of any steam trap. Jun 26, 2000 imagine 15psi steam blowing past a failed trap into the condensate return line. The automated steam trap consumes 32 mb steam operation, and deals a significant amount of damage to anyone walking through. Nova nft650 series variable orifice steam traps ntd 600 series thermoactive steam traps s610 series thermodynamic steam trap s650 series thermoactive steam trap ss600 series noise diffuser steam lock release. The american national standards institute defines a steam trap as a selfcontained valve that automatically drains the condensate from a steamcontaining enclosure while remaining tight to live steam, or if necessary, allowing steam to flow at a controlled or adjusted rate. The stainless steel float ball automatically adjusts the position of the main valve so that condensate is discharged continuously at the same rate as it enters the trap. Exporter of steam traps nicholson steam trap offered by circor floor technology india private limited, coimbatore, tamil nadu. N200300 monel these are no longer needed for units on campus. Steam traps also can be found near space heating equipment such as radiators, ceiling panels, fin tube radiation, unit heaters, convectors and coils. Fail close valve, seat ring, bellows, and required gaskets. Air is discharged through a small vent on the top of the inverted bucket while condensate fills the trap body and is discharged through the valve seat located on the top of the trap body.
Spence engineering acquired the nicholson line in 1989 and spence engineering and nicholson steam trap received iso9001 certification as manufacturers of fluid control and steam specialty devices in 1999. Looking for nicholson steam trap, 34 fnpt connections, 61116 end to end length, condensate capacity lbshr 80 15x140. Nicholson steam trap is a division of spence engineering company, inc. Download spence brochure nicholson steam traps and condensate pumps are designed for industrial applications such as condensate systems, district heating, main steam. Some of the products we sell can expose you to chemicals known to the state of california to cause cancer, birth defects or other reproductive harm. Duraflo inverted bucket trap 326 duraflo inverted bucket steam traps pressures to 250 psig 17. If condensate is allowed to collect, it reduces the flow capacity of steam lines and the thermal capacity of heat transfer equipment. Some of the products we sell can expose you to chemicals known to the state of california to cause cancer, birth defects or. We can drop at campus pack and ship and they will arrange shipping we are a small shop, so, pickups are by appointment only.
Steam system drip and tracing traps, blowdown and blowoff valves, pressure reducing regulators, and level gauges. For more information on nicholson steam trap, visit our website at. This means that sip system steam inplace sterilization pressures can be set lower because control limits are tighter. When steam enters the trap body it collects in the inverted bucket. Nicholson nova nft 250 steam traps saint louis supplier. Partlow west electronic and pneumatic controls for temperature pressure, pid, cascade, circular chart recorders, paper, pens and gas valves. Applications unit heaters pipe coils blast coils steam mains dry kilns.
1350 302 137 791 707 1506 408 532 717 1178 76 1221 1044 491 1569 627 664 39 1004 1120 793 1195 968 950 883 153 1470 157 845 1492 734 1437 349 264 818 1360 1527 1143 1081 48 1388 855 397 1150 1009 1399 810 580 421